Compaq 113803-001 Security Camera User Manual


 
3-43
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
DAAD Diagnostic Messages
Continued
Message Description Recommended Action
Logical drive X
failed due to
cache error
This logical drive failed due to a
catastrophic cache error.
Replace the array accelerator board and reconfigure
using the System Configuration Utility.
Logical Drive X
status = FAILED
This status could be issued for several
reasons. If this logical drive is
configured for No Fault Tolerance and
one or more drives fail, this status will
occur. If mirroring is enabled, and any
two mirrored drives fail, this status will
occur. If Data Guarding is enabled, and
two or more drives fail in this unit, this
status will occur. This status may also
occur if another configured logical drive
is in the WRONG DRIVE REPLACED or
LOOSE CABLE DETECTED state.
Check for drive failures, wrong drive replaced, or loose
cable messages. If there was a drive failure, replace the
failed drive(s) and then restore the data for this logical
drive from the tape backup. Otherwise, follow the
wrong drive replaced or loose cable detected
procedures.
Logical Drive X
status = INTERIM
RECOVERY
A physical drive in this logical drive has
failed. The logical drive is operating in
interim recovery mode and is
vulnerable.
Replace the failed drive as soon as possible.
Logical Drive X
status = LOOSE
CABLE DETECTED
A physical drive has a cabling problem. Turn the system off and attempt to reattach the cable
onto the drive. If this does not work, replace the cable.
Logical Drive X
status = NEEDS
RECOVER
A physical drive in this logical drive has
failed and has now been replaced. This
drive needs to be rebuilt from the mirror
drive or the parity data.
When booting up the system, select the "F1 - rebuild
drive" option to rebuild the replaced drive.
Logical Drive X
status =
OVERHEATED
The temperature of the Intelligent Array
Expansion System drives is beyond safe
operating levels and it has shut down to
avoid damage.
Check the fans and the operating environment.
Logical Drive X
status =
OVERHEATING
The temperature of the Intelligent Array
Expansion System drives is beyond safe
operating levels.
Check the fans and the operating environment.
Logical Drive X
status =
RECOVERING
A physical drive in this logical drive has
failed and has now been replaced. The
replaced drive is rebuilding from the
mirror drive or the parity data.
Nothing needs to be done. Normal operations can
occur.
Continued