Compaq 113803-001 Security Camera User Manual


 
5-3
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
Power Supply
Table 5-2
Power Supply Specifications
U.S. Metric
Input Specifications
Nominal Line Voltage 100 to 120 VAC 200 to 240 VAC
Range Input Line 90 to 132 VAC 180 to 270 VAC
Frequency Range 47 to 63 Hz 47 to 63 Hz
Power Factor 0.95 0.95
Input Current 8 A at 100 VAC 6 A at 200 VAC
Inrush Current <150 A at 132 VAC (cold start) <150 A at 132 VAC (cold start)
Holdup Time 20 ms from zero crossing at 120 VAC 20 ms from zero crossing at 240 VAC
General Specifications To 104°F and 5,000 ft To 40°C and 1,524 m
Full Output Rating To 90°F and 10,000 ft To 32°C and 3,048 m (derate linearly)
Minimum Load 1.0 A on + 5 V output
1.0 A on +12 V output
0.5 A on +3.3 V output
1.0 A on + 5 V output
1.0 A on +12 V output
.5 A on +3.3 V output
Ambient Temperature Range
Operating 50° to 104°F10° to 40°C
Storage -40° to 149°F -40° to 65°C
Dielectric Voltage Withstand
Input to Output 3000 VAC/min 3000 VAC/min
Input to Ground 1500 VAC/min 1500 VAC/min
Common and Differential Mode
(superimposed on AC line)
2500V, 1 µs, damped sinusoid 600 V, 10 µs pulse 20% step change in AC input
voltage