3-9
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1702-SCSI cable
error detected.
System halted.
None Incorrect cabling. 1. For integrated SCSI Controllers,
ensure that the internal connector
has SCSI termination attached.
2. For option card SCSI controllers,
ensure that only one of the two
internal connectors has
termination attached.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None Incorrect cabling. Ensure that the integrated SCSI
controller has SCSI termination
attached.
1704-Unsupported
Virtual Mode Disk
Operation. DOS
Driver Required.
System halted.
None System attempted to perform a
virtual mode disk operation
without virtual mode memory
services.
Use fixed-disk device driver that
supports virtual mode memory services.
1705-Locked SCSI
Bus Detected.
System halted.
None SCSI bus failure. Run Diagnostics. Replace failed
assembly as indicated.
1730-Fixed Disk 0
does not support
DMA Mode.
None Fixed disk drive error. Run the System Configuration Utility
and correct.
1731-Fixed Disk 1
does not support
DMA Mode.
None Fixed disk drive error. Run the System Configuration Utility
and correct.
1740-Fixed Disk 0
failed Set Block
Mode command
None Fixed disk drive error. Run the System Configuration Utility
and correct.
1741-Fixed Disk 1
failed Set Block
Mode command
None Fixed disk drive error. Run the System Configuration Utility
and correct.
1750-Fixed Disk 0
failed Identify
command
None Fixed disk drive error. Run the System Configuration Utility
and correct.
Continued