3-12 Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1778-Drive Array
resuming Automatic
Data Recovery
process
None This message appears
whenever a controller reset or
power cycle occurs while
Automatic Data Recovery is in
progress.
No action necessary.
1779-Drive Array
Controller detects
replacement drives
None Intermittent drive failure and/or
possible loss of data.
If this message appears and drive
X
has not been replaced, this indicates
an intermittent drive failure. This
message also appears once
immediately following drive
replacement whenever data must be
restored from backup.
1780-Disk 0 Failure None Hard drive/format error. Run Diagnostics. Replace failed
assembly as indicated.
1781-Disk 1 Failure None Hard drive/format error. Run Diagnostics. Replace failed
assembly as indicated.
1782-Disk Controller
Failure
None Hard disk drive circuitry error. Run Diagnostics. Replace failed
assembly as indicated.
1784-Drive Array
Drive Failure, Physical
Drive
None Defective drive and/or cables. Check for loose cables. Replace
defective drive
X
and/or cable(s).
1785-Drive Array not
Configured
None Configuration error. Run the System Configuration Utility
and correct.
1786-Drive Array
Recovery Needed
The following drive(s)
need Automatic Data
Recovery: Drive
X.
Select "F1" to
continue with
recovery of data to
drive(s).
Select "F2" to
continue without
recovery of data to
drive(s).
None Interim Data Recovery mode.
Data has not been recovered
yet.
Press F1 key to allow Automatic Data
Recovery to begin. Data will
automatically be restored to drive
X
now that the drive has been replaced
or now seems to be working.
-Or-
Press the F2 key and the system will
continue to operate in the Interim Data
Recovery mode.
Continued