3-8 Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
703-CMOS reports a
coprocessor that has
not been detected
2S Coprocessor or configuration
error.
1. Run the System Configuration
Utility and correct.
2. Replace the coprocessor.
1151-Com Port 1
Address Assignment
Conflict
2S Both external and internal serial
ports are assigned to COM1.
Run the System Configuration Utility
and correct.
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
2S Both external and internal serial
ports are assigned to COM2,
COM3 or COM4.
Run the System Configuration Utility
and correct.
1600-Server
Manager/R Failure
None Server Manager/R board failure.
Error code displays after error
message.
Run Diagnostics. Replace failed
assembly as indicated.
1610-Temperature
violation detected.
Waiting for system to
cool
2S Ambient system temperature
too hot.
Check fan in system environment.
1611-Fan [fan
description] failure
detected
2S Required fan has failed. Check fans.
1611-Fan [fan
description] not
present
2S Fan not present. Make sure fans are plugged in.
1612-Primary power
supply failure
2S Primary power supply has
failed.
Replace power supply as soon as
possible.
1613-Low System
Battery
None Real time clock system battery
is running low on power.
Run Diagnostics. Replace failed
assembly as indicated.
1615-Power Supply
Failure in Bay X
None A power supply has failed. Replace or check specified power
supply.
1616-Power Supply
Configuration Error
2L, 2S Single power supply system is
installed in Bay 2 and not in
Bay 1.
Move power supply from Bay 2 to
Bay 1.
1701-SCSI Controller
failure
None A test on the Fast SCSI-2
Controller failed
Run Diagnostics. Replace failed
assembly as indicated.