3-11
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1768-Slot x Drive
Array -Resuming
logical drive
expansion process.
None SMART-2 Controller error No action required. Appears whenever
a controller reset or power cycle
occurs while array expansion is in
progress.
1769-Slot x Drive
Array - Drive(s)
disabled due to failure
during expand. Select
F1 to continue with
logical drives
disabled. Select F2 to
accept data loss and
to re-enable logical
drives.
None SMART-2 Controller error. Data has been lost while expanding the
array, therefore the drives have been
temporarily disabled. Press F2 to
accept the data loss and re-enable the
logical drives. Restore data from
backup.
1771-Primary Disk
Port Address
Assignment Conflict
None Internal and external hard drive
controllers are both assigned
to the primary address.
Run the System Configuration Utility
and correct.
1772-Secondary Disk
Port Address
Assignment Conflict
None Address Assignment Conflict.
Internal and external hard drive
controllers are both assigned
to the secondary address.
Run the System Configuration Utility
and correct.
1773-Primary Fixed
Disk Port Assignment
Conflict
None Fixed disk drive error. Run the System Configuration Utility
and correct.
1774-Slot x Drive
Array - Obsolete data
found in Array
Accelerator. Select F1
to discard contents of
Array Accelerator.
Select F2 to write
contents of Array
Accelerator to drives.
None SMART-2 Controller error. Data found in Array Accelerator is older
than data found on drives. Press F1 to
discard the older data in the Array
Accelerator and retain the newer data
on the drives.
1776-Drive Array -
SCSI Port Termination
Error
None External and internal SCSI
drives are both configured to
Port 1.
Reconfigure drives.
1777-Drive Array
External Drive
Subsystem Error
None Cooling fan failure, internal
temperature alert or open side
panel.
Inspect for cooling fan failure or open
side panel.
Continued