68
Using time data (continued)
To externally lock the time code
Followthestepsbelow.
1 Turn the POWER/MODE switch to ON.
2 Set TCG on the setting menu RECORDING
SETUP screen to FREE RUN.
3 Use the COUNTER button to set TC display.
4 Supply a phase-relationship reference
time code (that conforms to the time
code requirements) and reference video
signals to the TC IN/OUT and GENLOCK IN
connectors, respectively.
•
Nowthebuilt-intimecodegeneratorislockedto
thereferencetimecode.
•
Whenlockedtoanexternaltimecodegenerator,
thetimecodeisatalltimeslockedtotheexternal
timecode,whichisdisplayedasahighlighted
valueonthecounterindicator.Donotengagethe
recordingmodeduringthefewsecondsittakes
forthesyncgeneratortostabilize.
•
Onceaslaverelationshipisestablished,theTC
IN/OUTandGENLOCKINconnectorsstayin
slavestatus.*
·
WhenTCPRESETisperformed.
·
WhentheRECSIGNALoptionintheSYSTEM
SETUPscreenissetto1394.
·
Thepoweristurnedoff.
·
Thetimecodemodeisswitched.
·
TheTCGswitchissettoR-RUN.
·
WhenRECFORMATandCAMERAMODE
havebeenswitched.
*Theslavefunctionisastatewherebythe
unit’sinternaltimecodegeneratorislocked
toandprogresseswithanexternallyinput
timecode,andcontinuestoprogressafter
inputoftheexternaltimecodehasstopped.
Setting the user bits when the time code is
externally locked
Toexternallylockuserbits,setthesettingmenu
UBMODE(RECORDINGSETUPscreen)toEXT.
RegardlessofanFREERUNorRECRUNsetting,
thetimecodeisslavedtouserbitvaluesinputto
theTCIN/OUTconnector.
•
“Timedataoverview”(Page61)·
“Settinguserbits”(Page62)
To unlock the externally locked time code
Discontinueexternaltimecodesupply,thensetthe
settingmenuTCG(RECORDINGSETUPscreen)
toRECRUN.
External synchronisation of the camera when
the time code is externally locked
Whenthetimecodeisexternallylocked,the
referencevideosignalsinputthroughthe
GENLOCKINconnectorgen-lockthecamera.
•
To lock other devices externally to the AG-
HPX250P/EN, as the master device, make
sure that the other devices are in the same
camera mode as the AG-HPX250P/EN. Note
that if some of the connected devices use
interlaced scanning while other devices use
progressive scanning, there may be breaks
in the video and time code.
•
When 24P, 24PA or 24PN (native) is selected
and the time code is externally locked, be
sure to select a non-drop frame time code.
The time code cannot be externally locked
when drop frame mode is selected. When
the time code is externally locked, the
video may be distorted, but this is because
of adjustment to 5-frame segments and not
a malfunction.