Chapter 4 Adjustments and Settings for Recording4-18
4 The value indicated differs between camcorder models.
1 Set the shutter speed mode to CLS.
CLEAR SCAN page (factory settings)
2 Turn the rotary encoder counterclockwise as seen from the front of
the camera to increase the value, or clockwise to decrease the value,
until the desired frequency appears.
The frequency ranges as follows.
DVW-707: 60.3 Hz to 10156 Hz in 261 steps
DVW-709WS: 60.1 Hz to 7000 Hz in 260 steps
DVW-790WS: 60.1 Hz to 7000 Hz in 260 steps, and
30.4 Hz to 58.3 Hz in 248 steps
DVW-707P: 50.0 Hz to 10101 Hz in 312 steps
DVW-709WSP: 50.2 Hz to 9000 Hz in 310 steps
DVW-790WSP: 50.2 Hz to 9000 Hz in 310 steps, and
25.4 Hz to 48.7 Hz in 295 steps
Pressing the MENU CANCEL/PRST/ITEM switch toward the
CANCEL/PRST position returns the setting to the default value,
60.3 Hz (DVW-707)/60.1 Hz (DVW-709WS/790WS) or
50.0 Hz (DVW-707P)/50.2 Hz (DVW-709WSP/790WSP).
When the RM-B150 Remote Control Unit is connected
You can set the shutter speed of CLS with the rotary encoder of the
RM-B150.
CLS:60.3Hz CLS:60.3Hz