Sony DVW-709WS/709WSP Camcorder User Manual


 
5-27
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
5-8. CUE/TC Head Position Adjustment
Notes
. Before this adjustment, be sure to finish the CTL head position adjustment. The CUE/TC head
position adjustment is performed as the standard position of the CTL head.
. The CUE/TC head position adjustment closely related to the height, azimuth and head-to-tape contact
adjustments of the CUE head. After CUE/TC head position adjustment, be sure to perform the adjust-
ments or checks of the CUE head.
Tools
. Alignment tape, ZR2-1 (NTSC) : 8-960-073-11
. Alignment tape, ZR2-1P (PAL) : 8-960-073-61
. Torque screwdriver bit (for M2) : J-6325-380-A
. Torque screwdriver (for 3 kg) : J-6325-400-A
. TP tool : J-6420-910-A
. Oscilloscope
Setting
1. Turn the power off.
2. Connect the 8-pin connector of the TP tool to the connector CN-7 on the HN-260 board.
3. Connect the 5-pin conne ctor of the TP tool to the connector CN-3 on the CTL-10 board.
4. Set the switches S1-1 and S1-2 on the HN-260 board to OFF.
5. Connect an oscilloscope.
CH-1 : SHAPED CTL/TP tool
CH-2 : TC/TP tool
TRIG : SV REF CF/TP tool
6. Turn the power on.
7. Insert the alignment tape ZR2-1/P.
5-8. CUE/TC Head Position Adjustment