Sony DVW-709WS/709WSP Camcorder User Manual


 
2-17
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
2-1. Service Mode
No. Page Item Setup Description
51 TG Adj. BC COMP.ADJ. X ([0]) This item is strictly for adjustment in the factory.
(Never change the setting.)
BC [ON]/OFF This item is strictly for adjustment in the factory.
(Never change the setting.)
FIELD/FRAME [FIELD]/FRAME Selects the CCD read-out system (Same as FIELD/FRAME item
of the “FUNCTION 2/2” page).
FIELD : Reading in units of field (normal setting).
FRAME: Reading in units of frame (select for improved vertical resolution).
Note : The FRAME reading has a more residual image than the FIELD reading.
TEST OUT [ENC]/R/G/B
Selects the type of video signal to be output from the TEST OUT connector.
(Same as TEST OUT item of the “FUNCTION 1/2” page)
R VSUB X ([0]) Sets the V substrate voltage value of the R signal.
G VSUB X ([0]) Sets the V substrate voltage value of the G signal.
B VSUB X ([0]) Sets the V substrate voltage value of the B signal.
52 VA ADJ.1/2 R GAIN (TMP) Displays the gain value of the R/G/B white balance amplifier.
G GAIN (TMP)
B GAIN (TMP)
R MOD.BAL. (TMP) Displays the modulation correction values to the R/G/B video
G MOD.BAL. (TMP) amplifier circuits.
B MOD.BAL. (TMP)
SAW/REC [SAW]/REC
Selects the TEST signal to be output when the TEST SAW item is turned on.
SAW : SAWTOOTH
REC : RECTANGULAR
TEST LEVEL X ([0])
Adjusts the gain of the TEST signal. (The amplitude of SAWTOOTH and
RECTANGULAR is automatically set for unity peak level.)
TEST SAW ON/[OFF] Turns ON/OFF the function to forcibly select the TEST signal for
the video signal system (used for video signal adjustment).
53 VA ADJ.2/2 R PREKNEE (KS ON) X ([0]) Adjusts the pre-knee level when KNEE SATURATION of the
G PREKNEE (KS ON) X ([0])
R/G/B signal is turned on.
B PREKNEE (KS ON) X ([0])
R PREKNEE X ([0])
Adjusts the pre-knee level when DCC of the R/G/B signal is turned on.
G PREKNEE X ([0])
B PREKNEE X ([0])
TEST OUT [ENC]/R/G/B
Selects the type of video signal to be output from the TEST OUT connector.
(Same as TEST OUT item of the “FUNCTION 1/2” page).
TEST SAW ON/[OFF] Turns ON/OFF the function to forcibly select the TEST signal for
the video signal system (used for video signal adjustment).
54 AD ADJ. G AD GAIN X ([0]) Adjusts the gain of the R/G/B video signal respectively that is input
R AD GAIN X ([0]) to the A/D converter.
B AD GAIN X ([0]) Note : Never change GAIN of the G channel AD converter.
AD CLOCK PHASE 0 to 7 Adjusts the clock phase of the G signal of the A/D converter.
R/B CLOCK PHASE 0 to 7 Adjusts the clock phase of the R/B signals of the A/D converter.
55 ND COMP. ND DETECTION [OFF]/EXEC/RESET EXEC : Used for color-correcting the ND filters.
ND1 DET. = [YET]/OK!
RESET : The correction values for the ND filters of ND1 to ND4 are reset.
ND2 DET. = [YET]/OK! OFF : When adjustment is completed, this item returns to the
ND3 DET. = [YET]/OK! OFF position automatically.
ND4 DET. = [YET]/OK!
56 VTR ADJ. EQ ADJUSTMENT [OFF]/EXEC Used for playback equalizer automatic adjustment.
REC CURRENT ADJ. [OFF]/EXEC Used for record current automatic adjustment.
CHECK ERROR RATE ON/[OFF] Used for playback equalizer adjustment and recording current
adjustment.