Installation
5. Cleaning of Contact Surfaces
(1) Clean the following places using a cleaning
cloth moistened with cleaning fluid.
. Flange of the lower drum (Shaded portion)
. Tape running surface and lead of the lower
drum
. Contact surface of the new upper drum as-
sembly (Shaded portion)
(2) Wipe the eight contact points (sixteen pins)
that mounts onto the LDR-8 board of the
flange and twelve circle patterns on the DR-
261 board using a dry cleaning cloth.
n
Never clean using a cleaning cloth moistened
with cleaning fluid.
Circle patterns (twelve)
LDR-8 board
Lower drum
Contact points (sixteen pins)
Lead
Tape running surface
Flange
DR-261 board
Cleaning Upper drum assembly
4-2. Parts Replacement