Sony DVW-709WS/709WSP Camcorder User Manual


 
7-10
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-5. TEST OUT Level Adjustment
16:9 and 4:3 mode
Preparation
. OUTPUT/DCC switch (inside panel) BARS
. On the setup menu, set as follows.
PAGE : S23*LEVEL 6
ITEM : TEST OUT R, G or B
Adjustment Procedure
Equipment : Waveform/Vector monitor
Test point : TEST OUT connector
1. Select the 16:9 mode.
PAGE : S14*WIDE SCREEN
ITEM : 16:9/4:3 MODE 16:9
2. On the setup menu, adjust as follows.
PAGE : S23*LEVEL 6
ITEM : RGB SYNC
Spec. : A = 40 ± 2 IRE (NTSC)
A = 300 ±14 mV (PAL)
3. On the setup menu, adjust as follows.
PAGE : S23*LEVEL 6
ITEM : RGB SETUP
Spec. : B = 7.5 ± 0.5 IRE (NTSC)
B = 0 ± 3 mV (PAL)
4. On the setup menu, adjust as follows.
PAGE : S23*LEVEL 6
ITEM : RGB LEVEL
Spec. : C = 100 ± 2 IRE (NTSC)
C = 700 ±14 mV (PAL)
5. Select the 4:3 mode.
PAGE : S14*WIDE SCREEN
ITEM : 16:9/4:3 MODE 4:3
6. On the setup menu, adjust as follows.
PAGE : S23*LEVEL 6
ITEM : RGB LEVEL <4:3>
Spec. : C = 100 ± 2 IRE (NTSC)
C = 700 ±14 mV (PAL)
Setting After Adjustment
. On the setup menu, set as follows.
PAGE : S23*LEVEL 6
ITEM : TEST OUT ENC
7-5. TEST OUT Level Adjustment
C
R
PAL
A
B
C
R
A
B
NTSC