Sony DVW-709WS/709WSP Camcorder User Manual


 
8-21
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-16-5. Detail Level Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1Lens IRIS
Spec. : A = 80 ±2 IRE (NTSC)
A = 560 ±14 mV (PAL)
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE : S16*LEVEL 1
ITEM : DETAIL LVL (Factory setting : 0)
Spec. : Adjust to the detail amount which is added
to each step in the grayscale chart for the
customer’s preferences.
8-16-6. Knee Aperture Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : DETAIL ON
ITEM : TEST OUT ENC
PAGE : S17*LEVEL 2
ITEM : KNEE APT. ON
. OUTPUT/DCC switch (inside panel) CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment : Waveform monitor
Setting point : 1 Lens IRIS
Spec. : A = 100 ± 2 IRE (NTSC)
A = 700 ±14 mV (PAL)
. GAIN switch (inside panel) M (9 dB)
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE : S17*LEVEL 2
ITEM : K.APT.LVL
Spec. : Adjust the peak-to-peak level of the
noise at the third steps from the top
(portion B) in the grayscale chart, as
desired. (Reference level is 40 mV)
8-16. Detail Signal Adjustment
A
A
B