8-24
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-18. Zebra Adjustment
Preparation
. ZEBRA switch (viewfinder) ON
. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST OUT R, G or B
PAGE : S15*VF SETTING
ITEM : ZEBRA SELECT 1
ITEM : ZEBRA1 APT. LVL 1 %
. OUTPUT/DCC switch (inside panel) CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1Lens IRIS
Spec. : A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
Adjustment Procedure
Equipment : Black and white monitor
Test point : TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA1 DET. LVL
Spec. : Set the condition that zebra pattern appears
at the portions A.
2. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST SAW ON
3. On the setup menu, adjust as follows.
PAGE : S15*VF SETTING
ITEM :
ZEBRA1 APT. LVL (Factory setting : 10 %)
Spec. : Adjust for the desired width of detection.
4. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST SAW OFF
5. On the setup menu, set as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA SELECT 2
6. On the setup menu, adjust as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA2 DET. LVL
Spec. : Set the condition that zebra pattern appears
at the portion B.
Setting After Adjustment
. On the setup menu, set as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA SELECT 1
PAGE : S12*FUNCTION 1/2
ITEM : TEST OUT ENC
8-18. Zebra Adjustment
A
A
A
B