ARRI 416 Film Camera User Manual


 
00
Problem Cause Remedy
Unsteady Image
Vertical Heavy emulsion build-up in the lm gate area, Clean lm gate area, use different lm stock
damaged lm perforation,
very poor gliding ability
of the raw lm stock,
lm stock with positive perforation,
dimensions of raw stock out of tolerance
Horizontal Heavy emulsion build-up in the lm gate area, Clean lm gate area,
lm edge is not straight use different lm stock
Pressure exposures around perforation holes Mechanical stress on the perforation holes Pressure exposures do not affect
the image steadiness
Image Problems
Blurred image Flange focal distance is set incorrectly, When cleaning the lm gate
lens is set incorrectly, ensure that the surfaces are absolutely clean,
poor quality or defective lens, check the lens and the ange focal distance
magazine pressure plate set incorrectly Take magazine to ARRI Service Centre
(image problem conned to one magazine)
Appendix