11
Resetting the Film Counter (Modes 1 and 3)
Change to the mode which shows the total exposed
lm counter (“MODE” button).
The total exposed lm counter can be set to zero by
pressing the “SET” button (for at least 1.5 seconds)
while in Standby.
The take length counter is automatically reset each time
the camera is started.
Setting the Total Exposed Film Counter (Mode 1)
The Total Exposed Film Counter can only be set in
Mode 1 (see Setting the Film Counter Conguration
above).
Use the “SEL“ button to select the total exposed lm
counter digit you wish to change, which will start to
ash.
Use the “SET“ button to change the value of the
ashing digit.
Changing the Unit of Measurement (Meters/Feet) (Mode 3)
Change from Mode 1 to Mode 3 by pressing the
“MODE” button twice.
Press the “SEL” button once; the symbol m/ft blinks.
Press the “SET” button within three seconds to change
the unit of measurement.
Displaying the Angle of the Mirror Shutter (Mode 1)
Press and hold the “PHASE” button while in Standby.
The set angle of the mirror shutter appears in the upper
display line.
The camera runs at inching speed.
Setting the shutter angle: see Chapter 7.