Panasonic AJ-HPX3100G Camcorder User Manual


 
148
Maintenance and Inspections: Maintenance
6. Inspection of the clock, time code, and user bits
1 Set the user’s bit as required.
> [Setting of the User bits] (page 64)
2 Set the time code.
> [Setting the Time Code] (page 67)
3 Set the TCG switch to [R-RUN].
4 Press the REC button.
Check that the counter display number changes as
recording progresses.
5 Press the REC button again.
Check that recording stops and the counter display
number stops changing.
6 Set the TCG switch to [F-RUN].
Check that the counter display number changes
regardless of recording status.
7 Set the DISPLAY switch to [UB].
Each time the HOLD button is pressed, make sure that
the displayed value changes in the following sequence:
VTCG > DATE > TIME > No display (time zone) >
TCG; and also verify that the displayed value is correct.
If DATE, TIME, or time zone is not correct, refer to
[Setting the Internal Clock’s Date and Time] (page 66)
for guidance on setting the correct values.
Note
Note that date and time data set for DATE, TIME, and time
zone is recorded in clips, and affects the playback
sequence, etc. at the time of thumbnail manipulations.
z Do not use thinner or other solvents to remove dirt.
z Wipe the lens with a commercially available lens cleaner.
z Do not wipe the mirror. If dirt or rubbish is sticking on the
mirror, remove it with a commercially available air blower.
Note
When outdoors, never carry or set up the camera with the
eyepiece facing up to prevent sunlight, which could damage
the camera, from entering.
Smears
Smears may appear when shooting an object with very high brightness.
This phenomenon becomes more obvious as the electronic shutter speed becomes faster.
The camera is shipped from the factory with a backup bat-
tery already mounted.
When the battery runs out, the [BACK UP BATT EMPTY]
display appears on the viewfinder screen for 5 seconds after
the power switch is turned ON.
The internal clock stops operating when the battery runs out.
Also, the TCG time code value returns to [00:00:00:00], and
the time code backup is disabled. The battery must be
replaced.
Please consult your distributor for replacement with a new
battery (CR2032).
The backup battery is visible when the panel on the LCD
monitor side is removed (right side when viewed from the
front).
Maintenance
Cleaning Inside the Viewfinder
Phenomenon Inherent to CCD Cameras
Replacing the Backup Battery
Note
Please contact the store where you purchased the camera
when replacing the battery.
AJ-HPX3100G(VQT3A79)_E.book 148 ページ 2010年9月17日 金曜日 午後9時21分