102 C626M-B (3/05)DX8000 PC Client Application
LINKING
CONFIGURING BASIC RELAY AND ALARM SETTINGS
The DX8000 can support up to 16 alarm inputs and relay outputs. Eight-channel DVRs include 8 alarm and 8 relay terminals while sixteen-
channel DVRs include 16 of each.
To program alarms and relays:
1. Click .
2. Click .
3. Click the Relay and Alarm Settings tab if it is not already visible.
Configuring Basic Relay Settings
To configure a relay output:
1. From the Relay Channel drop-down box, select the relay you want to configure.
2. Enter an optional new name for the relay in the Relay Name text box. Relay names can be up to 32 characters long and can include spaces
and special characters.
3. Click the NO/NC button to toggle the default output type for each relay (NO – normally open or NC – normally closed).
4. Click Apply.
Figure 127. Relay Settings
TIP: You can also rename sites, cameras, alarms, and relays from the site tree by clicking twice slowly on each object’s name.
ᕢ
ᕤ
ᕡ