Sony 510P Camcorder User Manual


 
Chapter 7 Menu Displays and Detailed Settings
133
7-3 Adjustments and Settings from Menus
or
JPN _
where _ represents a space.
ORGANIZATION (organization code)
When you select this item, the ORGANIZATION window
appears.
(Refer to the COUNTRY CODE window above.)
Enter an abbreviated 4-byte alphanumeric string for the
organization code.
Note
There are no problems in recording or playing back audio-
video signals,if ORGANIZATION is not set.
Organization codes must be acquired by applying to the
SMPTE registration office. When no organization code
has been acquired, it is forbidden to enter an arbitrary
string. As a rule, the code “00” must be entered. Freelance
operators who do not belong to an origination should enter
“~”.
USER CODE
When you select this item, the USER CODE window
appears.
(Refer to the COUNTRY CODE window above.)
Enter the 4-byte alphanumeric strings for user
identification.
The user code is registered with each organization locally.
It is usually not centrally registered.
When the user code is less than 4 bytes, enter the user code
from the beginning of the 4 bytes and enter the space
character (20h) in the remaining strings.
This user code is determined by the organization. The
methods used depend on the organization.
Note
User bits cannot be entered when no organization code has
been entered.
TIME ZONE
When you select this item, the TIME ZONE window
appears.
The UTC is calculated based on the local time, using the
time zone. If the time zone is not set, the UTC is not
recorded correctly.
Set the time difference from UTC. When setting the
summer time or daylight savings time, change the code to
one which will advance the time by 1 hour.
Note
When you change the time zone, adjust the built-in clock
to local time and turn the power of the camcorder off and
then the power on again.
7-3-11 Making Network Settings
The NETWORK page of the MAINTENANCE menu
allows you to make settings for connections to other DV
devices via a network.
Enabling automatic acquisition of the IP
address
When the unit is shipped from the factory, automatic
acquisition of the IP address is disabled. Proceed as
follows to enable it.
1
Holding down the MENU knob, set the menu switch
from OFF to ON.
The TOP menu appears.
2
Turn the MENU knob to move the b mark to
“MAINTENANCE”, and press the MENU knob.
If this is the first time the MAINTENANCE menu has
been displayed, the CONTENTS page appears.
If the menu has been used before, the last accessed
page appears.
3
If the CONTENTS page is displayed, turn the MENU
knob to move the b mark to “NETWORK”, and press
the MENU knob.
If a different page is displayed, turn the MENU knob
until the NETWORK page appears, then press the
MENU knob.
The NETWORK page appears. The current settings of
the items on the page appear to the right of the items.
4
Press the MENU knob, and turn it to move the b mark
to “DHCP”, then press the MENU knob.
The b mark to the left of “DHCP” changes to a z
mark, and the z mark to the left of the setting changes
to a ? mark.
TIME ZONE ESC
00.UTC GREENWICH
01.UTC-01:00 AZORES
02.UTC-02:00 M-ATRANTIC
03.UTC-03:00 ARZENTINE
04.UTC-04:00 HALIFAX
05.UTC-05:00 NEW YORK
06.UTC-06:00 CHICAGO
07.UTC-07:00 DENVER
08.UTC-08:00 LOSANGELES
09.UTC-09:00 ALASKA
M18 NETWORK TOP
DHCP : DISABL
IP ADDRESS :
192 168 1 10
SUBNET MASK :
255 255 255 0
DEF. GATEWAT :
0 0 0 0
LINK SPEED : AUTO
DUPLEX : AUTO