No. Page Item Settings Default Description
01 SW STATUS GAMMA OFF/ON ON Turns the gamma correction on or off.
CHROMA OFF/ON ON Turns the chroma of the composite signal on
or off.
MATRIX OFF/ON OFF Turns the linear matrix correction on or off.
KNEE OFF/ON ON Turns the knee correction on or off.
WHITE CLIP OFF/ON ON Turns the white clipping correction on or off.
DETAIL OFF/ON ON Turns the detail signal on or off.
APERTURE
OFF/ON ON Turns the aperture function on or off.
FLARE ON/OFF ON Turns the flare function on or off.
EVS OFF/ON OFF Turns the EVS shutter on or off.
TEST SAW OFF/REC/SAW OFF Selects the test signal.
02 WHITE COLOR TEMP <A> Display color
temperature
3200 Sets the color temperature of WHITE A.
COLOR FINE <A>
(–99 to +99)
0 Adjusts the value more precisely when the
color temperature adjustment through
COLOR TEMP is not satisfactory.
R GAIN <A>
(–99 to +99)
0 Only the value of R GAIN is changed.
B GAIN <A>
(–99 to +99)
0 Only the value of B GAIN is changed.
D5600 <A> OFF/ON OFF Turns the WHITE A electronic 5600K filter on
or off.
COLOR TEMP <B> Display color
temperature
3200 Sets the color temperature of WHITE B.
COLOR FINE <B>
(–99 to +99)
0 Adjusts the value more precisely when the
color temperature adjustment through
COLOR TEMP is not satisfactory.
R GAIN <B>
(–99 to +99)
0 Only the value of R GAIN is changed.
B GAIN <B>
(–99 to +99)
0 Only the value of B GAIN is changed.
D5600 <B> OFF/ON OFF Turns the WHITE B electronic 5600K filter on
or off.
03 BLACK/FLARE MASTER BLACK
(–99 to +99)
0 Adjusts the master black level.
R BLACK
(–99 to +99)
0 Adjusts the R black level.
B BLACK
(–99 to +99)
0 Adjusts the B black level.
MASTER FLARE
(–99 to +99)
0 Adjusts the flare level of the master.
R FLARE
(–99 to +99)
0 Adjusts the R flare level.
G FLARE
(–99 to +99)
0 Adjusts the G flare level.
B FLARE
(–99 to +99)
0 Adjusts the B flare level.
FLARE OFF/ON ON Turns the flare correction circuit on or off.
TEST OUT SELECT ENC/R/G/B ENC Selects the output signal of TEST OUT
connector.