5-6 Setting the Time Data
Setting the user bits
1
Set the DISPLAY switch to U-BIT.
2
Set the F-RUN/SET/R-RUN switch to SET.
The first (leftmost) digit flashes.
3
Use the SEL/SET dial to set the user bit data.
To change the value of the flashing digit, turn the dial,
and to shift to the next digit, press the dial. Repeat this
until all desired digits are set.
Hexadecimal digits A to F are displayed as follows:
To reset the user bit data to 00:00:00:00
Press the RESET button.
4
Set the F-RUN/SET/R-RUN switch to F-RUN or R-
RUN, corresponding to the desired operating mode for
the time code generator.
The set user bit data will be recorded for both LTC and
VITC.
To store the user bit setting in memory
The user bit setting (apart from the real time) is
automatically retained in memory even when the power is
turned off.
5-6-4 Synchronizing the Time Code
You can synchronize the internal time code generator of
this camcorder with an external generator for the
regeneration of an external time code. You can also
synchronize the time code generators of other camcorders/
VTRs with the internal generator of this camcorder.
Connections for time code
synchronization
Connect both the reference video signal and the external
time code as illustrated below.
Procedure for time code synchronization
To synchronize the time code, proceed as follows.
Hexadecimal A B C D E F
Display AbCdEF
SEL/SET
THUMBNAIL
S.SEL
ESSENCE MARK
SUB CLIP
REGEN
CLOCK
F-RUN
SET
R-RUN
PRESET
SHIFTCLIP MENU
1
3
2,4
RESET
button
Example 1: Synchronizing with an external time code
1) Set GENLOCK to ON on the GENLOCK page of the
MAINTENANCE menu, if GENLOCK is set to OFF.
GENLOCK IN
1)
Reference video signal
TC IN
External time code
Example 2: Interconnecting a number of camcorders
for time code synchronization
1) Set GENLOCK to ON on the GENLOCK page of the
MAINTENANCE menu, if GENLOCK is set to OFF.
TEST OUT
To another camcorder to be synchronized
TC OUT
Reference camcorder
TC IN
GENLOCK IN
1)
TC OUT
TEST OUT
GENLOCK IN
1)
TC IN
TC OUT
TEST OUT