Requirements
1 Field Sweep Displays 1 full field includ-
ing vertical interval.
2 Field Sweep Displays 2 full fields and the
vertical interval between
them. First sweep (left side
of CRT) is selectable be-
tween odd or even fields.
3 Field Sweep Displays 3 full fields and the
2 vertical intervals between
them. First sweep is select-
able between even or odd
fields, and third field polarity
is the same as that of the
first field.
Sweep Linearity
1 Line (5 ms/Div.)
±1%.
2 Line (10 ms/Div.)
±1%.
3 Line (15 ms/Div.)
±1%.
1 Field Sweep ±0.5 Division.
2 Field Sweep ±0.5 Division.
3 Field Sweep ±0.5 Division.
Slow Sweep ±5% of full screen over the
length of the sweep.
Specifications
5–8
1780R-Series Operator’s Manual
Table 5–4: Waveform Monitor Horizontal Deflection System (Cont.)
Characteristics
Supplemental
Information
Performance
Requirements
1 Field Sweep Displays 1 full field includ-
ing vertical interval.
2 Field Sweep Displays 2 full fields and the
vertical interval between
them. First sweep (left side
of CRT) is selectable be-
tween odd or even fields.
3 Field Sweep Displays 3 full fields and the
2 vertical intervals between
them. First sweep is select-
able between even or odd
fields, and third field polarity
is the same as that of the
first field.
Sweep Linearity
1 Line (5 ms/Div.)
±1%.
2 Line (10 ms/Div.)
±1%.
3 Line (15 ms/Div.)
±1%.
1 Field Sweep ±0.5 Division.
2 Field Sweep ±0.5 Division.
3 Field Sweep ±0.5 Division.
Slow Sweep ±5% of full screen over the
length of the sweep.