JAI TS-9720EN Security Camera User Manual


 
VIS-CAM System
26 Installing the Vehicle Imaging Subsystem
Figure 22. X-6 Power input connection.
3.3.4 X8 LS RS485 Out Connector
The RS485 output from the Light Sensor to the RS485-to-Ethernet converter connector is X8. The
connections from X8 to the converter are shown in Table 6 and Figure 23
Table 6 X8 to converter connector
X8 Pin # Signal Description
Connection to RS485-to-Ethernet converter
1 +24V dc 24V Power output
V+ power input
2 Gnd Power return
V-
power input
3 +12V dc 12V Power output
4 Gnd Power return
5 D0+ RS485 databus D0+
D+ Port 2
6 D0- RS485 databus D0-
D-
Port 2
7 D1+ RS485 databus D1+
D+ Port 1
8 D1- RS485 databus D1-
D-
Port1