Uniden UBCD396XT Photo Scanner User Manual


 
UBCD396XT
143
Plugging these values into our formula, we get:
For entry A:
Upper
Base
A
= Base
A + ( OffsetB –1 - OffsetA ) × StepA
Upper
Base
A
= 155.415 MHz + (436 1 380) × 15 kHz
Upper
Base
A
= 155.415 MHz + 55 × 0.015 MHz
Upper
Base
A
= 155.415 MHz + 0.825 MHz
Upper
Base
A
= 156.240 MHz
For entry B:
Upper
Base
B
= Base
B + ( OffsetC – 1 -OffsetB ) × StepB
Upper
Base
B
= 157.200 MHz + (454 – 1 – 436) × 12.5 kHz
Upper
Base
B
= 157.200 MHz + 17 × 0.0125 MHz
Upper
Base
B
= 157.200 MHz + 0.2125 MHz
Upper
Base
B
= 157.4125 MHz