Uniden UBCD396XT Photo Scanner User Manual


 
UBCD396XT
19
9. Conventional Systems
Please note that these pages are meant as general instructions.
Since a conventional system is really a collection of frequencies, the first thing you
need to know is the frequency for each channel you want to program.
Programming a Conventional System
To program a conventional system, you'll need to program the required elements in
the following order:
Create a system
1. Go to the Program System menu and choose New System.
2. The scanner will prompt you for the System Type. Select Conventional.
3. When the scanner prompts you confirm, tap YES.
4. The scanner creates the system with a default name. Select Edit Name if you
want to change it.
5. If you need to change any of the system properties, you can do that now.
Unless a property is Required, you can operate the system without changing
the default settings.
System properties
All of these options can be found under your scanner's Program System menu. If
necessary, the sub-menu and option name on each scanner are listed beside the
property.
Property Option name
Required
None
Recommended
Name Edit Name
Number tag Set Number Tag
Quick key Set Quick Key
Optional
Automatic Gain
Control (AGC)
Set Audio AGC
Delay time Set Delay Time
Hold time Set Hold Time