UBCD396XT
160
also display the name of the found system if the system's ID matches a known
system.
Set MOT Band Plan
If this custom search is a Motorola system, you need to select a band plan, just like
you do when you program a Motorola system for scanning. See Edit Band Plan for
more information.
Set Audio AGC
Turn on Automatic Gain Control (AGC) for this system. When you activate this
feature, the scanner automatically adjusts the volume for each channel based on the
signal strength. You can turn on the gain control for Analog and Digital signals
separately.
To change the settings for the audio AGC, see Adjust Audio AGC
P25 Waiting Time
When searching in a band that has a mix of analog and digital signals (i.e., where
the Audio Mode is set to All), it is possible to have false decode problems that
results in digital noise at the beginning of transmissions. To prevent this, a user-
configurable P25 wait time (from 0 to 1000 ms) has been added.
During the wait time, the scanner evaluates the received signal; if it detects P25
data, the scanner opens squelch immediately. If it does not detect any P25 data, the
scanner opens squelch as soon as the wait time expires.
Note: Any analog transmissions on this channel will lose the first part of the
transmission, up to the wait time you set here.
Select the number of milliseconds (after the start of a transmission) the scanner
should wait while checking for P25 data. Choose a number from 0 through 1000
ms in 100 ms increments. The scanner only applies the wait time when Tone/Code
Search in Srch/CloCall Opt is set to Off.
Search with Scan
Search and Store
Search a stored system and save the frequency information of any active channels.