Uniden UBCD396XT Photo Scanner User Manual


 
UBCD396XT
28
11. EDACS Trunked Systems
Please note that these pages are meant as general instructions.
This section deals with EDACS Wide or standard systems. This includes EDACS
systems that use ESK.
No special setting is needed to enable ESK tracking on an EDACS system. Note
that the scanner cannot decode EDACS ProVoice.
Programming an EDACS System
To program an EDACS system, you'll need to program the required elements in
following order:
Create a system
1. Go to the Program System menu and choose New System.
2. The scanner will prompt you for the System Type. Select EDCS.
3. The scanner will prompt you for the sub-type. Select Wide/Narrow.
4. When the scanner prompts you confirm, tap YES.
5. The scanner creates the system with a default name. Select Edit Name if you
want to change it.
6. If you need to change any of the system properties, you can do that now.
Unless a property is Required, you can operate the system without changing
the default settings.
System properties
All of these options can be found under your scanner's Program System menu. If
necessary, the submenu and option name on each scanner are listed beside the
property.
Property Option name
Required
None
Recommended
Name Edit Name
Number tag Set Number Tag
Optional