GND TXD RXD C+ C-GND TXD RXD C+ C-
P101
P106 P105
P107
XF102 XF103
XF101
5 4 3 2 1
J103
J103
J103
J102
J101
(LED)
HTR DOME
(FUSE)
(FUSE)
(FUSE)
(FUSE)
LINE NC NEUT
Figure 8.1: VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box
1
120 VAC/230 VAC Power In 6 Control Wire
Used for Audio input and output in
AUTODOME 7000 Series.
2 P101 Connector 7 24 VAC Power Out
3 Ground Connection 8 P107 Connector
4 Transformer 9 Earth-grounded conduit with power input
and earth-ground connection
5 Ethernet Wire 10 Earth-grounded conduit with Ethernet
video/control, audio input and output to
“head-end“ system
11 Earth-grounded conduit to camera
Method Two is to bypass the Power Supply Box and route the video, control, and alarm wires
directly to the Interface Board. You connect only the power wires inside the Power Supply
Box. All conduit and junction boxes used must be electrically earth-grounded.
AutoDome 7000 Series (IP and HD)
Installing the Roof Parapet and Pipe Mounts | en 41
Bosch Security Systems Operation Manual 2013.07 | 1.2.2 | F.01U.283.679