Bosch Appliances 7000 Security Camera User Manual


 
2.2K
Figure 11.2: N.O.S. - Normally Open Supervised Connections
1 Dry Contact 3 Dome Connector
2 Alarm 1 or 2 only (Pin 5 or 6) 4 Ground (Pin 7)
3. From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the
Alarm Input # and N.O. See the table below for contact and condition details.
AutoDome Programmed N.O.S.
Contact Alarm Condition
Open Normal
Closed Alarm
Cut or brake Tamper
Configuring a Normally Closed Supervised Alarm
1. Install a 2.2 K end-of-line resistor in the alarm circuit.
2. Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
camera.
2.2K
Figure 11.3: N.C.S. - Normally Closed Supervised Connections
1
Dry Contact 3 Dome Connector
2 Alarm 1 or 2 only (Pin 5 or 6) 4 Ground (Pin 7)
3. From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the
Alarm Input # and N.C. See the table below for contact and condition details.
AutoDome Programmed N.C.S.
Contact Alarm Condition
Open Alarm
Closed Normal
Short Tamper
74 en | Connection AutoDome 7000 Series (IP and HD)
2013.07 | 1.2.2 | F.01U.283.679 Operation Manual Bosch Security Systems