Bosch Appliances 7000 Security Camera User Manual


 
Configuring Non-supervised Alarms (inputs 3 through 7)
You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
Configuring a Normally Open Non-supervised Alarm
1. Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Figure 11.4: N.O. - Normally Open Non-supervised Connections
1
Dry Contact 3 Dome Connector
2 Alarm Inputs 3 to 7 4 Ground
2. From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the
Alarm Input # and N.O. See the table below for contact and condition details.
AutoDome Programmed N.O.
Circuit Alarm Indication
Open Normal
Closed Alarm
Configuring a Normally Closed Non-supervised Alarm
1. Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Figure 11.5: N.C. Normally Closed Non-supervised Connections
1
Dry Contact 3 Dome Connector
2 Alarm Inputs 3 to 7 4 Ground
2. From the Settings menu, select Advanced Mode > Interfaces > Alarm Inputs, select the
Alarm Input # and N.C. See the table below for contact and condition details.
AutoDome Programmed N.C.
Circuit Alarm Indication
Open Alarm
Closed Normal
AutoDome 7000 Series (IP and HD) Connection | en 75
Bosch Security Systems Operation Manual 2013.07 | 1.2.2 | F.01U.283.679