Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
power (UPS) supply is necessary. The UPS must have a Transfer Time between 2–6 ms and a
Backup Runtime of greater than 5 seconds for the power level as specified on the product
datasheet.
Maximum Wire Distances from Power Supply to AUTODOME
24 V to AUTODOME
VA / Watts 14 AWG
(2.5 mm)
16 AWG
(1.5 mm)
18 AWG
(1.0 mm)
HD models with IVA, Outdoor 60 / 55 58 m (190 ft) 36 m (119 ft) 23 m (75 ft)
Maximum Wire Distances from Power Supply to AUTODOME
24 V to AUTODOME
VA / Watts 14 AWG
(2.5 mm)
16 AWG
(1.5 mm)
18 AWG
(1.0 mm)
HD models with IVA, Indoor 35 / 19 99 m (325 ft) 62 m (205 ft) 39 m (129 ft)
HD models with IVA, Outdoor 60 / 55 58 m (190 ft) 36 m (119 ft) 23 m (75 ft)
Ethernet Connections
The camera connects to a 10 Base-T/100 Base-TX network either directly or via a hub. Video,
optional audio input, optional audio output, and control are transmitted over a standard
TCP/IP network using the built-in Web server. In addition, power can be supplied over the
Ethernet cable using the Bosch High PoE 60W midspan (sold separately). Power can also be
supplied over the Ethernet cable to in-ceiling models and indoor/outdoor pendant models
used in indoor applications (where the heater is not powered) using PoE+ PSEs (midspan
switches) compliant with the IEEE 802.3at, class 4 standard.
The camera can be connected simultaneously to a 24 VAC power supply and to a High PoE 60
W midspan. The camera uses power from the 24 VAC power supply. If this power supply fails,
the camera seamlessly switches power input to the High PoE 60 W midspan. The camera
switches back to the 24 VAC power supply once power is restored.
Refer to Using the IP Interface, for instructions on configuring an IP environment.
11.3
AutoDome 7000 Series (IP and HD) Connection | en 71
Bosch Security Systems Operation Manual 2013.07 | 1.2.2 | F.01U.283.679