Maintenance 3-36
NovaJet 800 Series Service Manual
Calibration Menu
Diagnostics Menu
About
Cartridge Info.
Test Print
Exit
*
Figure 3-23. Service Menu.
3. Select the “Calibration Menu” from the Service Menu.
4. The Calibration Menu shown in Figure 3-24 is where the deadband tests are
performed. Select “Slow Db Test” to run the slow deadband test.
Deadband Test
Slow Db Test
Single Line Test
All Lines Test
Slow Deadband
Exit
*
Figure 3-24. Calibration (Deadband) Menu.
5. When the plot is complete, select “Slow Deadband” at the Calibration Menu.
This brings up the options menu for the slow deadband adjustment. This menu
is similiar to the menu depicted in Figure 3-21.
6. Observe the plot and using either “Prev Option” or “Next Option”, rotate through
the selections until the value you want is selected. Press “Ok” to accept the
selection and return to the Calibration Menu.