Kodak 800 SERIES Camcorder User Manual


 
NovaJet 800 Series Service Manual
Assembly\Disassembly 5-45
4. Disconnect the AutoLoad Sensor connector at the J13 location on the
Main PWA. Grasp the AutoLoad Sensor connector with the thumb
and forefinger and pull straight out.
5. Remove the seven screws that secures the Y-Arm Assembly to the
Platen. See Figure 5-28.
Figure 5-28. Y-Arm Installation/Removal.
6. The pinch rollers are held on by a small C clamp located on the back
of the Y-Arm Assembly. See Figure 5-29. While holding the pinch
roller, remove the C clamp and move the pinch roller towards the front
of the Y-Arm Assembly until it clears the back of the Y-Arm Bracket.