Fujitsu FI-6110 Photo Scanner User Manual


 
Chapter 9 Operational Settings
Appendix
Glossary
Introduction
Index
Contents
TOP
148
How to Load
Documents
Configuring the
Scan Settings
How to Use the
Operator Panel
Various Ways to
Scan
Daily Care
Troubleshooting
Replacing the
Consumables
Scanner
Overview
Operational
Settings
Example 1:
Position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
Multifeeds are detected for the area in light blue.
End
(Middle)
Displays the end position of the detection
by the length from the leading edge of the
document.
Range: 0 to 510 mm, in 2 mm increments,
Start<End
z When both [Start] and [End] are set to "0", multifeed
detection is performed for the whole area regardless of
whether it is enabled or disabled.
z To disable multifeed detection for the whole document,
select [Disable] and set the start position to "0" and the
end position to equal the document length or longer.
z If you set a value larger than the document length for
the start position, selecting [Disable] detects the whole
length of the document and selecting [Enable] disables
the multifeed detection.
z In order to detect multifeeds, the detection range must
be at least 5 mm long.
Configure the setting so that the value of the end
position minus the start position is 6 mm or more.
z You can also set the start and the end positions by the
following methods:
- Draw an area with the mouse on the displayed
image.
- Drag the handles for [Start] and [End] positions on
the displayed image.
Range Description
50
50
200
Unit: mm
Feed direction