Replace the pad assy in following procedure.
1 Remove all documents from the ADF paper chute.
2 Open the ADF.
For details, refer to "1.4 Opening/Closing the ADF" (page 19).
3 Remove the pad assy.
Hold both ends of the pad assy and pull it out in the direction of the
arrow.
4 Attach a new pad assy.
Push the pad assy in until the hooks on both sides lock in place.
5 Close the ADF.
For details, refer to"1.4 Opening/Closing the ADF" (page 19).
6 Reset the consumable counter.
Start up the Software Operation Panel and reset the counter.
For details, refer to "Resetting the counters" (page 138).
7.2 Replacing the Pad Assy
Be careful not to have your fingers caught
when the ADF closes.
Pad Assy
Confirm that the pad assy is installed properly. Otherwise,
it may cause feeding errors such as paper jams.
Be careful not to have your fingers caught
when the ADF closes.
Pad Assy
Hook
Slot