Example 2:
Position: Middle
Selected range = Enable, Start = 0 mm, End = 0 mm
Multifeeds are detected for the area in light blue.
Example 3: (Bad example)
Position: Middle
Selected range = Enable, Start = 100 mm, End = 102 mm
Since the detection range (length) is less than 5 mm,
multifeeds cannot be detected accurately.
When detecting the overlapping of documents, the multifeed
detection rate may drop if the documents are glued tightly or
attached together by static electricity.
50
300
Unit: mm
Feed direction
50
300
2
100
Unit: mm
Feed direction