ZPL II Commands for RFID
^HR
86
58978L-008 Rev. A RFID Programming Guide 11/14/2008
Comments
• Based on the recommended transponder placement position for most RFID labels, the
printer’s default RFID programming position is zero for the R110PA X 4. For other RFID
printers, the default programming position is the label length minus 1 mm (0.04 in.).
To return to the default programming position at any time, use the RESTORE option in the
RFID TAG CALIB control panel parameter (see Calibrate RFID Tag on page 23).
• To see the current programming position (shown in dot rows), refer to the printer
configuration label:
or use the SGD command rfid.position.program on page 135.
• At the end of calibration, a results table is returned to the host. Each line in the results
table appears as:
Row, Read Result, Write Result
where
Row = the millimeter where calibration occurred
Read Result = results of calibration (R = read, " " = unable to read)
Write Result = results of calibration (W = write, " " = unable to write)
The programming position is indicated in dot rows.