Zebra Technologies TTP 2000 Photo Scanner User Manual


 
Programming
Software Command Syntax
68
P1002902-002 TTP 2000 Technical Manual 09/14/2009
Results in a 2-byte response representing the version of the installed bootware.
The first byte represents major versions, and the second byte minor versions.
That is, a response with the value 01 30 (hex) indicates version 1.48.
Results in a string containing the device ID in the Windows Plug and Play string format. The
two first bytes represent the string length.
ESC ENQ 12
Bootware Version Enquiry
1B 05 0C hex
27 5 12 decimal
Example •
Send<ESC><ENQ><12>
Read01 30 (hex)
Note • TTP 2000 does not store the bootware in the printer so this query will always return
<0><0>.
ESC ENQ c
Device ID Enquiry
1B 05 63 hex
27 5 99 decimal
Example •
Send<ESC><ENQ>c
Read0—106 (decimal) This indicates that the string is 104 characters (plus two characters
indicating the string length)