Programming
Logotypes
74
P1002902-002 TTP 2000 Technical Manual 09/14/2009
Logotypes
Up to 16 logotypes can be stored in the flash PROM of the printer. The logotypes can be
positioned and printed out with commands <ESC>g or <ESC>L.
The exact number of logotypes and their sizes is determined by the total amount of memory
used for fonts, logotypes and loaded firmware. Make a test printout to see how much memory
is available.
Loading
Windows software that converts black and white BMP bitmap files to logotypes and load them
into the printer is available on the Zebra web site. If you need to load logotypes in a non-
Windows environment, use the <ESC>&1 command.
The time required by the printer to process logotype data, excluding transfer time from the PC,
is typically 15 to 20 seconds, per logotype. During this time, any data sent to the printer will be
lost.
File Format
A header containing information about the logotype number, size and logotype name shall
define each loaded logotype. Immediately after the header follows the actual bitmap of the
logotype.
<ESC>&<1><Header><Bitmap>
Header
Note • Logotype No. 0 is printed in the top of the self test printout, so this can be used to
customize the self test printout.
Byte 0 Logotype number used to identify the logotype when printing.
Byte 1 X size measured in bytes.
Byte 2 Y size measured in pixels.
Byte 3—15 A logotype name that will be printed on test printouts.