Kodak ML-500 Photo Printer User Manual


 
Calibration
Back
IndexContents
Next
92
Reference
Completed Calibration Event
A completed calibration event is any calibration
target that has been printed and analyzed. You can
reanalyze a target if the following are true:
The calibration target was analyzed visually.
There have been no other calibrations
completed for the printer and media
combination since the one that you want to
analyze.
Approved Densitometers
Use densitometers with a Status A spectral
response with the ML-500 calibration application.
Densitometers with a Status T spectral response
are unsuitable for the ML-500 calibration
application.
The following densitometers are usable with the
calibration application:
X-RITE 404 *
X-RITE 414 *
X-RITE DPT-36
X-RITE DPT-41
X-RITE 528
X-RITE 530
* Only the 404 and 414 densitometers marked with
"A-RESP" are usable with the calibration
application.