Bosch Appliances VJR SERIES Security Camera User Manual


 
AutoDome Junior HD Configuring the AutoDome Junior HD | en 171
Bosch Security Systems, Inc. Installation Manual F.01U.275.803 | 6.0 | 2012.11
them automatically, but only replies to SNMP requests. If you
enter one or two SNMP host addresses, SNMP traps are sent
automatically. Select Off to deactivate the SNMP function.
1. SNMP host address / 2. SNMP host address
If you wish to send SNMP traps automatically, enter the IP
addresses of one or two required target units here.
SNMP traps
You can select which traps are to be sent.
1. Click Select. A list is opened.
2. Click the checkboxes to select the required traps. All the
checked traps will be sent.
3. Click Set to accept the selection.
Authentication
If a RADIUS server is employed in the network for managing
access rights, authentication must be activated here to allow
communication with the unit. The RADIUS server must also
contain the corresponding data.
To configure the unit, you must connect the AutoDome Junior
HD directly to a computer using a network cable. This is
because communication via the network is not enabled until the
Identity and Password parameters have been set and
successfully authenticated.
Identity
Enter the name that the RADIUS server is to use for identifying
the AutoDome Junior HD.
Password
Enter the password that is stored in the RADIUS server.
RTSP port
If necessary, select a different port for the exchange of the
RTSP data from the list. The standard RTSP port is 554. Select
Off to deactivate the RTSP function.