AutoDome Junior HD Audio, Alarms and Relay Connections | en 83
Bosch Security Systems, Inc. Installation Manual F.01U.275.803 | 6.0 | 2012.11
9.2 Connecting Alarms (inputs 1 through 2)
You can configure alarms 1 through 2 as Normally Open (N.O.)
or Normally Closed (N.C.) alarms.
9.2.1 Connecting a Normally Open Alarm
1. Connect the alarm to the appropriate input (1 through 2)
and ground at the AutoDome Junior.
Figure 9.2 N.O. - Normally Open
2. From the AutoDome Junior HD Settings page select
Interface>Alarm Inputs. Refer to Section 12 Configuring the
AutoDome Junior HD, page 108, for directions about
accessing the Settings page.
Ref. # User Contact Dome Color
1 Normally
Open
Alarm In 1 or Alarm In 2
(Ref. #3)
Brown IN 1 or
Orange IN 2
2 Common Ground (Ref. #4) Green
AutoDome Junior Programmed N.O.
Circuit Alarm Indication
Open Normal
Closed Alarm