SonicWALL 2.5 Security Camera User Manual


 
230
SONICWALL SONICOS ENHANCED 2.5 ADMINISTRATORS GUIDE
C
HAPTER
37:
Setting Up Hardware Failover
Intial Hardware Failover Setup
Before you begin the configuration of Hardware Failover on the Primary SonicWALL security
appliance, perform the following intial setup procedures.
On the back of the Backup SonicWALL security appliance, local the serial number and write the
number down. You need to enter this number in the Hardware Failover>Settings page.
Check to make sure the Primary SonicWALL and Backup SonicWALL security appliances are
registered, running the same SonicOS Enhanced versions, and running the same SonicWALL
Security Security services.
Make sure Primary SonicWALL and Backup SonicWALL security appliance’s LAN, WAN, and
other interfaces are properly configured for seamless failover.
Connect the X5 ports on the Primary SonicWALL and Backup SonicWALL appliances with a
CAT6-rated crossover cable. The Primary and Backup SonicWALL security appliances must have
a dedicated connection between each other using the X3 (PRO2040) or X5 (PRO3060/4060/5060)
interface. SonicWALL recommends cross-connecting the two together using a CAT5/6 crossover
Ethernet cable, but a connection using a dedicated 100Mbps hub/switch is also acceptable.
Power up the Primary SonicWALL security appliance, and then power on the Backup SonicWALL
security appliance.
Do not make any configuration to the Primary’s X3 (PRO 2040) or X5 (PRO 3060/4060/5060)
interface; the Hardware Failover programming in an upcoming step takes care of this issue. When
done, disconnect the workstation.