21 Using About 273
{Dimmer Feedback} - appears when the current address is patched to a dimmer in an ETC Sensor
rack with a CEM+ or CEM3. Sensor feedback must be enabled. See Sensor Feedback, page 343
and Errors and Warnings, page 86 for more information.
{Dimmer Feedback} displays the following information:
• Name (dimmer name)
• Module type
• Rack/Position
• Rack dimmer level (displayed as a percentage)
• Rack dimmer source
• Recorded load
• Actual load
{Dimmer Feedback} displays the following information, which can be modified from Ion by clicking
on the value and entering in a new value:
• Firing Mode
• Control Mode
•Curve
• Threshold
• Scale Minimum
• Scale Maximum
• Preheat Enable
• Preheat Timing
• Advanced Features (AF) Enable
Ion supports the following softkey commands from this display:
• {Ignore Errors}
• {Clear Errors}
Note:
For Sensor feedback, the CEM+ must be running software version 3.0 or later.
Note:
Clearing CEM+ / CEM3 errors from Ion will be temporary unless the errors have
been fixed at the CEM+ / CEM3 Errors displayed on Ion will clear on their own
once they have been cleared from the CEM+ / CEM3. Some CEM+ / CEM3 errors
can only be cleared at the CEM+ / CEM3.