ION Ion Camcorder Accessories User Manual


 
352 Ion Operations Manual
Show Control Gateway
Group IDs
Allows you to set the group number for the MIDI In and MIDI Out ports. Group numbers can be from
1-32. Default for both ports is 1.
Contact Closure (remote trigger connector)
Allows you to set the Group and Address In values for the remote trigger input on the back of Ion.
Relay Out (remote trigger connector)
Allows you to set the Group and Address In values for the remote trigger port on the back of Ion.
RFR
This screen is used for setting up the Radio Focus Remote (RFR) to work with Ion. For more
information on RFR, see Remote Control, page 377 For additional RFR settings, see {RFR
Settings}, page 109.
USB RFR Settings
These settings need to match between the desk and the RFR. For more information on changing
the frequency and ID at the remote, see Change Frequency and ID Setting, page 380.
High Frequency Channel
The frequency that the RFR is using. There are 1-12 channels.
Network ID
The Network ID is a separate digital channel on a single high frequency (HF) setting. There are 1-
99 IDs available.
Note:
To input RS-232 into an Ion desk, you will need to use a Net3 I/O Gateway.
1
2
3
4
5
6
7
8
15
14
13
12
11
10
9
Ground
Ground
+ 12Vdc
+ 12Vdc
S1
S2
S3
S4
Relay Out, Normally Closed
Relay Out, Normally Open
Relay Out, Common
8 7 6 5 4 3 2 1
15 14 13 12 11 10 9
Remote Trigger
connector pinout