Raritan Computer DSX-0N-E Security Camera User Manual


 
CHAPTER 7: PORT CONFIGURATION AND PORT ACCESS APPLICATION 31
Chapter 7: Port Configuration and Port Access
Application
Port configuration allows Administrators to define the serial/console port settings in order to
communicate with remote target devices.
Note: You can access the Raritan Serial Console (RSC) from the Port screen. See the Raritan
Serial Console section of this chapter for RSC information.
Port Keywords
You can create port keywords and associate them with:
Events
Local/remote syslog messages
SNMP traps.
Port keywords work as a filter. If a keyword is detected, then and only then will a corresponding
message be logged in a local/NFS port log. A corresponding event will be sent via SMTP (if
configured) and corresponding trap will be sent via SNMP (if configured).
This is very useful for local/remote NFS logging, as it logs just the information you need and no
junk messages, thus providing ease of traceability.
Note: The SMTP notification (event.amp.keyword) is selected from the Event configuration
page.
1. Click the Setup tab, and then click Port Keywords. The Port Keywords screen appears.
Figure 25 Port Keywords Screen
2. Type a keyword in the Keyword field.
3. Type the Port(s) you want to associate with that keyword.
4. Click OK.