EPSON Stylus Pro 7000 Revision B
Disassembly & Assembly Disassembly Flow 146
4.2.3.14 Removing the Pump Motor Assembly
1. Remove the Maintenance Assembly as described in “Removing the
Maintenance Assembly” on page 143.
2. Release the harness for the Pump Motor Assembly from the cable clamp.
3. Remove the three (CP(W) M3x8) screws securing the Pump Motor
Assembly to the Maintenance Base Assembly and remove the Pump
Motor Assembly.
Figure 4-69. Removing the Pump Motor Assembly
Pump Motor
Assembly
Clamp
Screws
(M3x8)