EPSON Stylus Pro 7000 Revision B
Adjustment Self-Diagnostic Mode Menus 195
5.4.4 Print Menu
The Print menu performs the same test-printing functions as the "Test Print"
option on the Adjustment menu. For details, see “Test Pattern Print” on
page 192.
5.4.5 Parameter Menu
Using this menu you can reset or change the parameters for the printer
mechanism controls. However, the parameters on this menu can also be
modified from the Adjust menu. When servicing the printer, you do not need
to separately update or reset the parameters from this menu.
Figure 5-42. Parameter Menu Options
"INITIALIZE" ITEMS
The items you can reset (re-initialize) using this menu are described below.
Capping Position (see
“Adj Cap Position” on page 176)
Paper Feed Distance (see “Feed Adjustment” on page 189)
Serial No. (see “Test Pattern Print” on page 192 for more information)
Maintenance Record (see Table 5-9, “Maintenance Record Items,” on
page 173)
"UPDATE" ITEMS
The items you can update are described below.
Capping Position (see
“Adj Cap Position” on page 176)
Head Rank voltage (see “Adj Input Rank” on page 177)
Print Position Items (Bi-D Adjustment/Gap Adjustment)
Paper Feed Distance (see “Feed Adjustment” on page 189)
Mechanism Parameters (see the next page)
Ink Parameters (see the following)
[Pause] to return to previous menu
[SelecType]
[Enter]
[Item]
Other
menus
[Pause]
Parameter: Init.
Parameter: Update
CHECK
POINT
The parameters will update and be stored in the Flash memory
on the Main Board the next time the printer is turned off.