Disassembly & Assembly Disassembly Flow 153
4.2.3.22 Removing the P_FRONt Sensor Assembly
1. Remove the R Side Cover as described in “R Side Cover Removal” on
page 114.
2. Remove the L Side Cover as described in “L Side Cover Removal” on
page 116.
3. Remove the I/C Holder Cover as described in “I/C Holder Cover Removal”
on page 116.
4. Remove the H Top Cover as described in “H Top Cover Removal” on
page 117.
5. Remove the Rear Cover as described in “Rear Cover Removal” on
page 118.
6. Remove the paper Guide L2 as described in “Paper Guide L2 Removal”
on page 119.
7. Disconnect the harness for the P_FRONT Sensor Assembly from the
connector on the main board and drop the harness in the hole on the
right.
8. Push the paper hold lever down to the front.
9. Remove the three (CUPS M4x6) screws securing the Paper Guide L, and
remove the Paper Guide L by slowly taking it out toward upper front.
NOTE: To remove the left screw, insert a screw driver from the space
of the I/H Assembly, the third one from the right.
10. Remove the two (CP(W) M2x8) screws securing the P_FRONT Sensor
Assembly and remove the P_FRONT Sensor Assembly.
NOTE: P_FRONT Sensor Assembly position is adjusted at factory.
Therefore, be sure to mark its current position before
removing the screws.
Figure 4-79. Removing the Paper Guide L
Figure 4-80. Removing the P_FRONT Sensor Assembly
ADJUSTMENT
REQUIRED
If you replace the P_FRONT Sensor Assembly, perform the
necessary adjustment listed in Table 5-2 in Chapter 5.
Paper Guide L
Screws
(M4x6)
(+) Screw
Driver
P_FRONT
Sensor
Assembly
Screws
(M2x8)