EPSON Stylus Pro 7000 Revision B
Adjustment Self-Diagnostics 164
5.3 Self-Diagnostics
This section gives detailed descriptions of all adjustments necessary to
properly service and maintain this printer.
1. Make sure the Paper Set Lever is in the Set (forward) position.
2. Press the following buttons on the Control Panel while turning on the
printer.
[Paper Feed +] + [Paper Feed -] + [Enter]
3. When "Check: Test" appears on the LCD, the printer has entered the Self-
Diagnostic mode.
To exit the Self-Diagnostic mode, turn off the printer.
Use the Control Panel buttons to activate a Self-Diagnostic function, as
described in the table below.
Figure 5-1. Self-Diagnostic Controls
Table 5-3. Self-Diagnostic Mode Controls
Normal
Function
Self-Diagnostic
Function
Meaning
Pause
Return up one
level
Moves up one level (without selecting at
item).
SelecType Next menu Displays the next menu.
Paper Source Previous menu Displays the previous menu.
Paper Feed + Next item or value
Displays the next item or increases the value
of the item shown on the LCD.
Paper Feed -
Previous item or
value
Displays the previous item or decreases the
value of the item shown on the LCD.
Cut/Eject Enter Selects/activates the item.
Cleaning Feed paper & cut
Proceeds to
next menu
Goes to next
or previous
item
Returns to
previous menu
Selects or
activates
the item
Jumps up a
level